Quantcast
Channel: Jason Andrews Blog
Browsing all 33813 articles
Browse latest View live
↧

Image may be NSFW.
Clik here to view.

RE: Display current view in window title bar

Hello, IceWM queries the charset of the application locale; this is then used for translation of single-byte application strings to unicode before printing them. If the string contains characters not...

View Article


Image may be NSFW.
Clik here to view.

RE: How to delete Via in layout?

You'd need: foreach(via cvid~>vias dbDeleteObject(via)) By the way, if you're using the C-style I wouldn't use the getSGq function - it's completely equivalent to the ~> operator. So the shapes...

View Article


Image may be NSFW.
Clik here to view.

RE: Plot expression after ADE-XL run

Karam, No, I've not seen this. Sounds like a bug. Please contact customer support ... Regards, Andrew.

View Article

Image may be NSFW.
Clik here to view.

Dynamically Changing the pulse width - vpulse/vsource

I would like to generate variable pulse width based on the circuit conditions. I can use vpulse/vsource from analoglib to generate pulse with different duty cycles. But I am wondering, how to change or...

View Article

Image may be NSFW.
Clik here to view.

RE: Dynamically Changing the pulse width - vpulse/vsource

Vijay, It rather depends on what you want to vary and what the condition is. If it's a simple event - when something reaches a limit you want to change the pulse width - then you can do that in...

View Article


Image may be NSFW.
Clik here to view.

turn off pulldown selection in ICADV12.3 ?

Hi, is there a way to turn off the pulldown selection in ICADV12.3, which appears in several places (library manager, and also in create new instance form), .e.g in the attached image, for create...

View Article

Image may be NSFW.
Clik here to view.

RE: turn off pulldown selection in ICADV12.3 ?

It doesn't do that for me. It hides the form (in some situations I have to hit enter twice - once to confirm the library name selection from the auto-complete, and once to hide the form). Which...

View Article

Image may be NSFW.
Clik here to view.

Frankenstein

"Hail to thee, blithe spirit! Bird thou never wert"...and Frankenstein. What do these two have to do with each other? And why did I pick today to ask such an odd question? You may recognize the quote...

View Article


Image may be NSFW.
Clik here to view.

Unable to import Eagle PCB to OrCAD PCB

When I try to import Eagle PCB into OrCAD PCB 17.2 a error message is displayed in the command window " E- *Error* eval: undefined function - _ns_create_eagleform " Help me in resolving this issue.

View Article


Image may be NSFW.
Clik here to view.

Are spectre and spectre XPS output file formats are the same

Hi Team, We are planning to migrate from spectre simulator to spectre XPS in near future for one of dotLib generation setup.We need two information to proceed for the migration. 1) Are the language...

View Article

Image may be NSFW.
Clik here to view.

RE: How do I uncheck "Process statement" from sidebar in Simvision?

In addition to Colin's Tcl-based solution, I'd like to point out an important point about setting preferences in SimVision: if you use the main menu Edit->Preferences, then make changes there. If...

View Article

Image may be NSFW.
Clik here to view.

Intel 10nm

At IEDM last month, Intel announced details of their 10nm process. Later the same morning, they also gave details on a 22nm process, 22FFL, which is a second generation 22nm process (their first FinFET...

View Article

Image may be NSFW.
Clik here to view.

Fail to run with user defined the "connect rules"

Hi Everyone I want to introduce self-defined connectRules for AMS simulation to remove 1nsec sampling time from the predefined connectRules of the project I have following the tutorial from Candence,...

View Article


Image may be NSFW.
Clik here to view.

RE: Allegro 17.2 test point creation

The normal drill file shows the correct units, its the test point drill file that doesn't change its units

View Article

Image may be NSFW.
Clik here to view.

RE: Fail to run with user defined the "connect rules"

Hi Yi, The best thing to do would be log this as a case with customer support (I assume there's a good reason why you're using IC616 (an unsupported release) too, although I suspect this is just a...

View Article


Image may be NSFW.
Clik here to view.

RE: Unable to import Eagle PCB to OrCAD PCB

There is an issue with the 17.2 S031 release and this has been brought to Cadence's attention. An upcoming hotfix should correct this. If you are on a different hotfix let us know which specific...

View Article

Image may be NSFW.
Clik here to view.

RE: turn off pulldown selection in ICADV12.3 ?

Hi, it is sub-version ICADV12.3-64b.500.13. I tried ICADV12.3-64b.500.10, in gnome, in kde, same behavior. So I assume there is no .cdsenv option to turn off those red/white down arrows on the...

View Article


Image may be NSFW.
Clik here to view.

Cadence 17.2 Continuous Refresh problem

Running Windows 10 and having Pspice A/D simulation opened. The Capture CIS 17.2 keeps refreshing the buttons, without letting me work on anything. What should I do ?

View Article

Image may be NSFW.
Clik here to view.

RE: Orcad Capture - Slow Graphics response on windows 10

I'm having this issue as well. But, I'm having it with an nvidia 1050 graphics card and the latest drivers. And this is with a new kickass MOBO and i7 CPU. It's particularly bad when I'm trying to draw...

View Article

Image may be NSFW.
Clik here to view.

RE: turn off pulldown selection in ICADV12.3 ?

As far as I am aware, there is no way to change these combobox fields back into standard type-in fields (that would be potentially difficult, and probably doesn't make much sense provided they work...

View Article