Quantcast
Channel: Jason Andrews Blog
Browsing all 33813 articles
Browse latest View live
↧

Image may be NSFW.
Clik here to view.

question about the cdf parameters of the switch instance in analoglib

I am using the 6.1.7 version of cadence and I noticed that the switch instance in analoglib has the following cdf parameters. I was wondering if anyone could tell me why there are two fields for open...

View Article


Image may be NSFW.
Clik here to view.

RE: question about the cdf parameters of the switch instance in analoglib

By the looks of things you're looking at a modified version of analogLib provided by Mentor for use with Eldo. The standard Cadence analogLib has 6 parameters: Open voltage Closed voltage Open switch...

View Article


Image may be NSFW.
Clik here to view.

RE: PCB Editor Immediately AutoSaving and Closing When Opening Design

Enabling auto-save did not help. I had high hopes for the nolast file stuff, but that didn't help either. This seems to be happening on tons of designs that previously had no problem. It also seems to...

View Article

Image may be NSFW.
Clik here to view.

RE: PCB Editor Immediately AutoSaving and Closing When Opening Design

Actually, I squirreled away the registry settings and my pcbenv folder and performed an uninstall/reinstall of Cadence 17.2, then upgraded to the latest 17.20.038. We'll see how that goes before...

View Article

Image may be NSFW.
Clik here to view.

configure the Symbol_MaxSymSize directive in the setup.cpm

I got an error when creating a symbol I thought I changed the sheet to F and I am not sure why it was too large, but should be able to work thorugh that, I was looking at the sybol_maxsymsize so I...

View Article


Image may be NSFW.
Clik here to view.

RE: noisetype_off re-ignored

absolutely amazing, that was it. thank you so much!

View Article

Image may be NSFW.
Clik here to view.

Step mapping

Hello, I am trying to map a step model of an SMA from grabcad. I clicked Setup, Step Mapping and get the Device/Package step mapping window. I can see the name of and can visualize the step model, but...

View Article

Image may be NSFW.
Clik here to view.

RE: configure the Symbol_MaxSymSize directive in the setup.cpm

Looking at the 17.2 $CDSROOT/share/cdssetup/projmgr/cds.cpm the following 2 entries Symbol_SymSheetSize 'A' Symbol_MaxSymSize '-18000,18000,18000,-18000' are in the START_PDV ... END_PDV section, so I...

View Article


Image may be NSFW.
Clik here to view.

RE: configure the Symbol_MaxSymSize directive in the setup.cpm

The PDV setup dialog doesn't appear to show any way of changing the Syymbol_MaxSymSize value, so I was able to modify it using the cpmaccess command on my project's cpm file, example shown below:...

View Article


Image may be NSFW.
Clik here to view.

Pastemask Keepout in Package

Does anyone know if it's possible to add pastemask keepout areas when editing a package? I can explain why I want to do this, but I figured I'd check if it's possible first.

View Article

Image may be NSFW.
Clik here to view.

Vias and Soldermask

Here is a basic question that I've never considered before: does Allegro treat the soldermask for vias differently than for the plated holes they're based on? I've always just used my standard plated...

View Article

Image may be NSFW.
Clik here to view.

RE: Generate layout.oa for an older version of a layout (sync managed) and...

Hi Andrew, I am always getting the latest layout with gdmexport from command line. I am using this command: gdmexport -destination temp/ -file layout/layout.oa -version 1.1 latest layout is version...

View Article

Image may be NSFW.
Clik here to view.

RE: configure the Symbol_MaxSymSize directive in the setup.cpm

Great thank you I was able to change the values and will check if the next errors tomorrow, Thanks again for your help

View Article


Image may be NSFW.
Clik here to view.

RE: Monte Carlo dist=unif option

Hi Andrew, Thank you, that is the solution I was hoping to find. Regards, Michael

View Article

Image may be NSFW.
Clik here to view.

RE: Generate layout.oa for an older version of a layout (sync managed) and...

This works for me. I did this: UNIX> gdmexport -destination opamp090/play/layout_v1_1 -lib opamp090.play:layout -version 1.1 (gdm): [vsexport: Exported play/layout/master.tag to...

View Article


Image may be NSFW.
Clik here to view.

GDPR Starts Today

You are probably subscribed to a number of email newsletters. No doubt you have been receiving emails saying that the system is changing the way that they are handling their mailing lists and that if...

View Article

Image may be NSFW.
Clik here to view.

RE: spectre oceaneval function documentation

I thought I'd replied to this already - but don't see it (perhaps I forgot to hit Reply). Anyway, I've not heard from R&D but have reiterated what you said about distributed (I'd given similar...

View Article


Image may be NSFW.
Clik here to view.

RE: Avoid/Blacklist model instance from PDK

That's because your checking function is outside of the scope of the abRegExampleSchematicCheckNew function; in my code it was within the scope and because the file had a .ils suffix, it was using...

View Article

Image may be NSFW.
Clik here to view.

RE: Step mapping

Hi Steve, Thanks for the reply. I did have the dra open at the time, but could not see the place bound. The next day, I could. Maybe closing and re-opening the dra or app or the re-boot helped. I think...

View Article

Image may be NSFW.
Clik here to view.

Doube symbol

Hi guys, i have a new question. Is possible in capure cis to have a doube symbol? For example about connector. For a one project schematic (core desine) i can to have more different versions and more...

View Article
Browsing all 33813 articles