dynamic parameter in SpectreMDL

$
0
0
Hi, Basis: there is a need for me to change the temperature within the transient simulation. I followed the post as linked below, and got it working in Spectre from ADE https://community.cadence.com/cadence_technology_forums/f/custom-ic-design/10265/varying-the-temperature-in-a-transient-simulation Problem: as the data extraction is huge, I have been using spectremdl to run the simulation, now with the "temp" as dynamic parameter, there is no change in expected results, the changes are obvious in ADE simulation though. I have extracted the netlist from the test bench that worked well in ADE. simple test case: the tran control reads: tran tran stop=1u param=temp param_vec=[0 27 315n 27 316n -20 416n -20 417n 100 517n 100 518n 40 618n 40] write="spectre.ic" writefinal="spectre.fc" annotate=status maxiters=5 my spectremdl control file reads: t1 = temp @ 275n t2 = temp @ 375n t3 = temp @ 475n but t1, t2, t3 all end up as same value. (T2=T3=T1=27) So, I am wondering whether the option is supported in spectremdl? or am i missing anything here? Thanks! Aarthy

Viewing all articles
Browse latest Browse all 33813

Trending Articles